logo

2-6 Core Mineral Insulated Metal Sheathed Cable for High Temperature 200℃-1000℃ with Class I/II/III Accuracy

50m
MOQ
협상 가능
가격
2-6 Core Mineral Insulated Metal Sheathed Cable for High Temperature 200℃-1000℃ with Class I/II/III Accuracy
풍모 갤러리 제품 설명 따옴표를 요구하십시오
풍모
제품 사양
핵심: 2,3,4,6
격리: MGO
보증: 1 년
온도 범위: 200 ℃ -1000 ℃
정확성: 클래스 I 、 II 、 III
외부 디아: 0.5-12.7mm
패키지: 판지 상자. 짚자리
기능: 온도 테스트
케이블 길이: 1-5m 또는 사용자 정의
열전대 유형: K/N/E/J/T/S/R/B.
강조하다:

2-6 Core Mineral Insulated Metal Sheathed Cable

,

200℃-1000℃ MIMS Cable

,

Class I/II/III Accuracy Thermocouple Mineral Insulated Cable

기본 정보
원래 장소: 닝보 중국
브랜드 이름: LEADKIN
인증: ISO9001, IATF16949, CE
모델 번호: LK-K
결제 및 배송 조건
포장 세부 사항: 70*70*8cm 상자
배달 시간: 근무일 2-7 일
지불 조건: L/C, D/A, D/P, T/T, Western Union, MoneyGram
공급 능력: 1,000,000M/year
제품 설명
Mineral Insulated Metal Sheathed Cable for High Temperature and High Demand Environments
Quick Details
  • Type: K/N/E/J/T/S/R/B
  • Place of Origin: Zhejiang, China (Mainland)
  • Accuracy: I-0.4%t, II-0.75%t, III-1.5%t
  • Core number: 2,3,4,6
  • Inorganic mineral insulating lead material: Ni, Cu
  • Insulator: 99.6% high purity MgO
  • Certificate: ISO9001, IATF16949, CE
  • Application: Connecting with thermocouple and instrument machine
  • Sheath material: 0Cr18Ni10Ti, SS304S, SS316L, SS316, Cu
  • Sheath Dia(mm): φ3.0, φ4.0, φ6.0, φ8.0
Sheath Wire Type Specifications
Product Name Code Type Sheath Material Outside Dia. Temperature
NiCr-NiSi /NiCr-NiAl KK K SS304 SS316 0.5-1.0 400
1.5-3.2 600
4.0-8.0 800
SS310 Inconel600 0.5-1.0 500
1.5-3.2 800
4.0-6.4 900
8.0-12.7 1000
NiCrSi-NiSi NK N SS304 SS316 0.5-1.0 400
1.5-3.2 600
4.0-8.0 800
SS310 Inconel600 0.5-1.0 500
1.5-3.2 800
4.0-6.4 900
8.0-12.7 1000
NiCr-Konstantan EK E SS304 SS316 0.5-1.0 400
1.5-3.2 600
4.0-8.0 800
Fe-Konstantan JK J SS304 SS316 0.5-1.0 400
1.5-3.2 600
4.0-8.0 800
Cu-Konstantan TK T SS304 SS316 0.5-1.0 400
1.5-3.2 600
4.0-8.0 800
RhPt10-Ph SK S Inconel600 6.0-12.7 1100
Note: Different temperature measuring media and service conditions may impact service life and temperature range. Table data is for reference only.
Accuracy Specifications
Type Class I Class II
K ±1.5℃ (-40~375℃) ±2.5℃ (-40~375℃)
±0.4% (375℃-1000℃) ±0.75% (375℃-1000℃)
N ±1.5℃ (-40~375℃) ±2.5℃ (-40~375℃)
±0.4% (375℃-1000℃) ±0.75% (375℃-1000℃)
E ±1.5℃ (-40~375℃) ±2.5℃ (-40~375℃)
±0.4% (375℃-800℃) ±0.75% (375℃-800℃)
J ±1.5℃ (-40~375℃) ±2.5℃ (-40~375℃)
±0.4% (375℃-800℃) ±0.75% (375℃-800℃)
T ±0.5℃ (-40~125℃) ±1.0℃ (-40~125℃)
±0.4% (125℃-350℃) ±0.75% (125℃-350℃)
S ±1.0℃ (0-1100℃) ±1.5℃ (0-1100℃)
Product Overview

Thermocouple temperature probes utilize the thermoelectric effect to measure temperature through two different metal wires joined at one end, generating a voltage corresponding to temperature differences.

Construction
  • Wires: Two different conductive metals forming a junction
  • Junction: Measuring (hot) junction connects to measuring device (cold junction)
  • Insulation: High-temperature resistant materials (ceramic/fiberglass)
  • Sheath: Protective metal or ceramic casing
Working Principle
  • Seebeck Effect generates thermoelectric voltage at junction
  • Voltage magnitude relates to temperature gradient
  • Metal sheath and mineral insulation protect against EMI/RFI and corrosion
Applications
  • Solid waste incinerators
  • Sintering powdered metals
  • Firing ceramic materials
  • Gas/oil fired furnaces
  • Fuel fired heat exchangers
  • Box furnaces
  • Nuclear/hydrocarbon energy plants
Product Images
2-6 Core Mineral Insulated Metal Sheathed Cable for High Temperature 200℃-1000℃ with Class I/II/III Accuracy 0
Company Information
Main Products
2-6 Core Mineral Insulated Metal Sheathed Cable for High Temperature 200℃-1000℃ with Class I/II/III Accuracy 1 2-6 Core Mineral Insulated Metal Sheathed Cable for High Temperature 200℃-1000℃ with Class I/II/III Accuracy 2
Packaging

We use heat shrink tubing and plastic film to ensure high insulated resistance. Each coil cable includes marking notes, pass card, and test report.

2-6 Core Mineral Insulated Metal Sheathed Cable for High Temperature 200℃-1000℃ with Class I/II/III Accuracy 3
Production Line

Our high-quality professional products are manufactured using advanced production lines and equipment, complying with international quality standards and appreciated in global markets.

Order Process
  1. Accurate quotation
  2. Confirm price, trade terms, lead time, and payment
  3. Receive Proforma Invoice with official seal
  4. Customer arranges deposit payment
  5. Production updates with photos
  6. Final product photos before shipment
  7. Balance payment and shipment with tracking
  8. Order completion upon satisfaction
  9. Customer feedback for continuous improvement
Frequently Asked Questions
What are the advantages of using thermocouples?
  • Wide temperature range
  • Fast response time
  • Simple and rugged design
  • Relatively inexpensive
  • Suitable for extreme conditions
What are the disadvantages of thermocouples?
  • Non-linear output requiring calibration
  • Lower accuracy compared to RTDs
  • Requires reference junction compensation
  • Susceptible to electromagnetic interference