logo

Industrial-Grade 2-6 Core Mineral Insulated Metal Sheathed Cable with 200℃-1000℃ Temperature Range and Class I/II/III Accuracy

50m
MOQ
협상 가능
가격
Industrial-Grade 2-6 Core Mineral Insulated Metal Sheathed Cable with 200℃-1000℃ Temperature Range and Class I/II/III Accuracy
풍모 갤러리 제품 설명 따옴표를 요구하십시오
풍모
제품 사양
핵심: 2,3,4,6
격리: MGO
보증: 1년
온도 범위: 200 ℃ -1000 ℃
정확성: 클래스 I 、 II 、 III
외부 디아: 0.5-12.7mm
패키지: 판지 상자. 짚자리
기능: 온도 테스트
케이블 길이: 1-5m 또는 사용자 정의
열전대 유형: K/N/E/J/T/S/R/B.
강조하다:

2-6 Core Mineral Insulated Metal Sheathed Cable

,

200℃-1000℃ MIMS Cable

,

Class I/II/III Accuracy Thermocouple Mineral Insulated Cable

기본 정보
원래 장소: 닝보 중국
브랜드 이름: LEADKIN
인증: ISO9001, IATF16949, CE
모델 번호: LK-K
결제 및 배송 조건
포장 세부 사항: 70*70*8cm 상자
배달 시간: 근무일 2-7 일
지불 조건: L/C,D/A,D/P,T/T,웨스턴 유니온,MoneyGram
공급 능력: 1,000,000M/year
제품 설명
Industrial-Grade Mineral Insulated Metal Sheathed Cable

High-performance cable designed for heavy-duty applications with thermocouple and instrument machine connections.

Quick Details
Type K/N/E/J/T/S/R/B
Place of Origin Zhejiang, China (Mainland)
Accuracy I-0.4%t, II-0.75%t, III-1.5%t
Core number 2,3,4,6
Insulator 99.6% high purity MgO
Certificate ISO9001, IATF16949, CE
Sheath material 0Cr18Ni10Ti, SS304S, SS316L, SS316, Cu
Sheath Dia(mm) φ3.0, φ4.0, φ6.0, φ8.0
Type for Sheath Wire Type K
Product Name Code Type Sheath Material Outside Dia. Temperature
NiCr-NiSi /NiCr-NiAl KK K SS304 SS316 0.5-1.0 400
1.5-3.2 600
4.0-8.0 800
SS310 Inconel600 0.5-1.0 500
1.5-3.2 800
4.0-6.4 900
8.0-12.7 1000

Note: Different temperature measuring media and service conditions may affect service life and temperature range. Table data is for reference only.

Accuracy for Sheath Wire Type K
Type Class I Class II
K ±1.5℃ (-40~375℃)
±0.4% (375℃-1000℃)
±2.5℃ (-40~375℃)
±0.75% (375℃-1000℃)
N ±1.5℃ (-40~375℃)
±0.4% (375℃-1000℃)
±2.5℃ (-40~375℃)
±0.75% (375℃-1000℃)
E ±1.5℃ (-40~375℃)
±0.4% (375℃-800℃)
±2.5℃ (-40~375℃)
±0.75% (375℃-800℃)
J ±1.5℃ (-40~375℃)
±0.4% (375℃-800℃)
±2.5℃ (-40~375℃)
±0.75% (375℃-800℃)
T ±0.5℃ (-40~125℃)
±0.4% (125℃-350℃)
±1.0℃ (-40~125℃)
±0.75% (125℃-350℃)
S ±1.0℃ (0-1100℃) ±1.5℃ (0-1100℃)
Product Overview

A thermocouple temperature probe uses the thermoelectric effect to measure temperature through two different metal wires joined at one end, generating a voltage corresponding to temperature differences.

Construction
  • Wires: Made of two different conductive metals (copper, nickel, chromel, alumel)
  • Junction: Measuring (hot) junction where wires join, connected to measuring device (cold junction)
  • Insulation: High-temperature resistant materials (ceramic, fiberglass)
  • Sheath: Protective metal or ceramic casing for environmental protection
Working Principle

Based on the Seebeck Effect: when two different metals are joined and exposed to temperature gradient, a thermoelectric voltage is produced at the junction. This voltage relates to the temperature difference and is converted into temperature readings using calibration data.

Applications
  • Solid waste incinerators
  • Sintering powdered metals
  • Firing ceramic materials
  • Gas or oil fired furnaces
  • Fuel fired heat exchangers
  • Box furnaces
  • Nuclear or hydrocarbon based energy plants
Product Images
Industrial-Grade 2-6 Core Mineral Insulated Metal Sheathed Cable with 200℃-1000℃ Temperature Range and Class I/II/III Accuracy 0
Company Information
Main Products
Industrial-Grade 2-6 Core Mineral Insulated Metal Sheathed Cable with 200℃-1000℃ Temperature Range and Class I/II/III Accuracy 1 Industrial-Grade 2-6 Core Mineral Insulated Metal Sheathed Cable with 200℃-1000℃ Temperature Range and Class I/II/III Accuracy 2
Package

We add heat shrink tubing and plastic film to ensure high insulated resistance. Each coil cable includes marking notes, pass card and test report.

Industrial-Grade 2-6 Core Mineral Insulated Metal Sheathed Cable with 200℃-1000℃ Temperature Range and Class I/II/III Accuracy 3
Production Line

We maintain high-quality professional products with advanced production lines and equipment, complying with international quality standards. Our production systems are continuously updated to meet increasing market demands.

Order Process
  1. Request accurate quotation
  2. Confirm price, trade terms, lead time, and payment terms
  3. Receive Proforma Invoice with official seal
  4. Arrange deposit payment
  5. Receive production line photos showing your products
  6. Confirm estimated delivery time
  7. Receive mass production photos
  8. Make balance payment and receive shipping details
  9. Provide feedback on quality and service
Frequently Asked Questions
What are the advantages of using thermocouples?

Wide temperature range, fast response time, simple and rugged design, relatively inexpensive, suitable for various environments including extreme conditions.

What are the disadvantages of thermocouples?

Non-linear output requiring calibration, potentially lower accuracy than other sensors, requires reference junction compensation, susceptible to electromagnetic interference.